Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 11(15)2022 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-35956132

RESUMO

We aimed to identify a simple metric accounting for peri-procedural hemoglobin changes, independent of blood product transfusion strategies, and assess its correlation with outcomes in patients undergoing left ventricular assist device (LVAD) implantation We included consecutive patients undergoing LVAD implantation at a single center between 10/1/2008 and 6/1/2014. The anemia stress index (ASI), defined as the sum of number of packed red blood cells transfused and the hemoglobin changes after LVAD implantation, was calculated for each patient at 24 h, discharge, and 3 months after LVAD implantation. Our cohort included 166 patients (80.1% males, mean age 56.3 ± 15.6 years) followed up for a median of 12.3 months. Increases in ASI per unit were associated with a higher hazard for all-cause mortality and early RV failure. The associations between the ASI and all-cause mortality persisted after multivariable adjustment, irrespective of when it was calculated (adjusted HR of 1.11, 95% CI 1.03-1.20 per unit increase in ASI). Similarly, ASI at 24 h after implant was associated with early RV failure despite multivariable adjustment (OR 1.09, 95% CI 1.05-1.14). We present a novel metric, the ASI, that is correlated with an increased risk for all-cause mortality and early RV failure in LVAD recipients.

2.
ESC Heart Fail ; 7(6): 3573-3581, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33263224

RESUMO

AIMS: Perioperative blood transfusions are common among patients undergoing left ventricular assist device (LVAD) implantation. The association between blood product transfusion at the time of LVAD implantation and mortality has not been described. METHODS AND RESULTS: This was a retrospective cohort study of all patients who underwent continuous flow LVAD implantation at a single, large, tertiary care, academic centre, from 2008 to 2014. We assessed used of packed red blood cells (pRBCs), platelets, and fresh frozen plasma (FFP). Outcomes of interest included all-cause mortality and acute right ventricular (RV) failure. Standard regression techniques were used to examine the association between blood product exposure and outcomes of interest. A total of 170 patients were included in this study (mean age: 56.5 ± 15.5 years, 79.4% men). Over a median follow-up period of 11.2 months, for every unit of pRBC transfused, the hazard for mortality increased by 4% [hazard ratio (HR) 1.04; 95% CI 1.02-1.07] and odds for acute RV failure increased by 10% (odds ratio 1.10; 95% CI 1.05-1.16). This association persisted for other blood products including platelets (HR for mortality per unit 1.20; 95% CI 1.08-1.32) and FFP (HR for mortality per unit 1.08; 95% CI 1.04-1.12). The most significant predictor of perioperative blood product exposure was a lower pre-implant haemoglobin. CONCLUSIONS: Perioperative blood transfusions among patients undergoing LVAD implantation were associated with a higher risk for all-cause mortality and acute RV failure. Of all blood products, FFP use was associated with worst outcomes. Future studies are needed to evaluate whether pre-implant interventions, such as intravenous iron supplementation, will improve the outcomes of LVAD candidates by decreasing need for transfusions.


Assuntos
Coração Auxiliar , Disfunção Ventricular Direita , Adulto , Idoso , Transfusão de Sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...